RECOVER DALI 1350, RECOVER PRO 1650, RECOVER BASIC 1350, RECOVER PRO 1350, RECOVER DALI 1650, RECOVER BASIC 1650

RECOVER BASIC 1650

099-2211517

Quickinfo

3000 K
CRI ≥ 97 / 3 SDCM (initial MacAdam)
1,480 lm / ↑ 8,170 lm
83 lm/W
L80 / 50000 h
non DIM
IP40

Colour

General

  • Wall
  • Surface
  • pure white
  • RAL 9010
  • IP40
  • indirect 8170 lm
  • direct 5591, 14802, 23 lm
  • total 5591, 14802, 81703 lm
  • 5591, 14802, 81703 lm

LED

  • 3000 K
  • CRI ≥ 97
  • L80 / 50000 h
  • ≤ 3 SDCM (initial MacAdam)
  • Rg: 102
  • Rf: 96
  • R{1-15}: 96
  • MR 0.63
  • MDER 0.57

Electrical

  • non DIM
  • 220-240 V
  • system 9.41, 23.52, 993 W
  • system 591, 632, 833 lm/W 4
  • PC1

Physical

  • length 1645 mm
  • width 223 mm
  • height 80 mm
  • 12 kg

Circuit Breaker Types

Automatic Circuit Breaker Type

B10
B13
B16
B20
C10
C13
C16
C20

Number of Fixtures

14
18
25
28
23
30
38
46
1 READING LIGHT 2 EXAMINATION LIGHT 3 AMBIENT LIGHT 4 incl. consideration of optical losses, internal control unit losses & operating device efficiency

LED wall mounted light for standard nursing area; IP 40 protection; 1 pc per bed; mounting height of upper edge of luminaire: 180cm; rectangular luminaire profile with direct / indirect light distribution, surface white powder coated; end cap in same colour; direct and indirect light exit with clear toughened glass cover; cable inlet on the wall side for 220-240V power supply and for the examination light circuit and the reading light; power feed from the rear (wall mounting profile preassembled); Luminaire offers 3 kinds of lighting; 1) Reading light; flush mounted, equipped with lens technology to avoid glare to neighbouring bed; reading light switchable by means of a connection to a potential-free contact (e.g., via a patient terminal provided by the customer); 2) Examination light; switchable by means of a connection to a button; 3) Indirect room lighting; switchable by means of a connection to a button; maximum power consumption 127W; luminous flux 9380lm; L80 min. 80% of luminous flux after 50000 operating hours; colour temperature 3000K; colour rendering CRI > 90, CRI typically 95; colour point binning: directly on the BBL, colour homogeneity: initial <3-Step SDCM scale, colour point stability: final after 10000 hrs <4-Step SDCM scale; PC I; complies with the following provisions: EN (IEC) 60598-1 and the supplement EN (IEC) 60598-2-25; dimensions of housing W 1650mm, visible H 47mm, wall profile H 80mm, D 223mm; Manufacturer XAL, type RECOVER basic 1650

Product data & specification documents

Datasheets

Planning files & lighting data

Download all

Related products

New

REVO

wall surface
DALI LIGHT SENSOR

RECOVER

SENSOR

UNICO

wall surface

UNICO

wall recessed

TASK

wall

SASSO 100

round wall

SASSO 60

round wall